Intermatic 7-Day Programmable Timer Manual: A Comprehensive Guide
This manual details the Intermatic T104 timer‚ a heavy-duty‚ 40 Amp‚ 208-277V DPST switch ideal for controlling lights‚ pumps‚ and HVAC systems effectively.
Intermatic timers represent a longstanding tradition of reliable and precise time control solutions for residential‚ commercial‚ and industrial applications. For decades‚ these devices have provided automated control of lighting‚ appliances‚ HVAC systems‚ and various other electrical loads‚ enhancing convenience‚ security‚ and energy efficiency.
The T104 model‚ a popular choice‚ is a mechanical timer switch known for its durability and straightforward operation. Unlike digital timers‚ the T104 utilizes a robust electromechanical mechanism‚ offering consistent performance without reliance on complex electronics. This makes it particularly suitable for demanding environments and applications where simplicity is key.
This guide focuses on the Intermatic T104‚ providing a comprehensive overview of its features‚ programming‚ troubleshooting‚ and safety considerations‚ empowering users to maximize its potential.
Understanding the T104 Model
The Intermatic T104 is a 24-hour mechanical timer switch designed for indoor use‚ housed within a durable metal enclosure. It operates on a 208-277 VAC power supply and boasts a 40 Amp load capacity‚ making it suitable for controlling substantial electrical loads. Its core functionality revolves around 12 ON/OFF operations‚ configurable using physical trippers around the timer dial.
This model features a manual override function‚ allowing users to temporarily bypass the programmed schedule without altering the set timings. The T104’s design prioritizes simplicity; programming is achieved through the strategic placement of these trippers‚ defining the ON and OFF periods.
Its robust construction and mechanical operation contribute to its longevity and reliability‚ offering a dependable time control solution for various applications.
Key Features and Benefits
The Intermatic T104 timer offers several key advantages for users seeking reliable time-based control. Its 40 Amp capacity handles heavy-duty loads like pumps‚ fans‚ and HVAC systems with ease. The mechanical design ensures durability and consistent performance‚ minimizing the need for frequent replacements.
A significant benefit is the manual override function‚ providing instant control when scheduled operations need temporary adjustment. The 12 ON/OFF operations offer versatile scheduling options for diverse applications. The robust metal enclosure protects internal components‚ ensuring longevity in various environments.
Furthermore‚ the T104’s straightforward operation simplifies programming‚ requiring no complex digital interfaces or software. This makes it an accessible solution for both professionals and DIY enthusiasts.

Setting Up Your Intermatic Timer
Proper installation and setup are crucial for optimal performance; this involves secure mounting‚ careful wiring‚ and initial power-up following all safety guidelines.
Initial Power-Up and Safety Precautions
Before energizing your Intermatic timer‚ meticulously verify all wiring connections against the provided diagram‚ ensuring adherence to local electrical codes. Always disconnect power at the breaker before any installation or wiring adjustments. This timer operates at 208-277V‚ presenting a significant electrical hazard if handled improperly.
Confirm the timer enclosure is securely mounted and grounded to prevent accidental contact with live components. Never attempt to open or modify the timer mechanism while power is applied. Inspect the wiring for any damage or fraying before connecting it to the timer.
Exercise extreme caution when working with electricity; if you are uncomfortable with any aspect of the installation‚ consult a qualified electrician. Failure to follow these safety precautions could result in serious injury or property damage.
Mounting the Timer
The Intermatic T104 timer is designed for indoor use within a metal enclosure‚ requiring a stable and secure mounting surface. Select a location that is easily accessible for programming and maintenance‚ yet protected from extreme temperatures and moisture. Ensure sufficient space around the timer for wiring connections and ventilation.
Utilize appropriate screws and anchors suitable for the wall material. The timer’s dimensions are approximately 2.5 inches deep‚ 4.7 inches wide‚ and 7.6 inches high; plan accordingly. Securely fasten the timer to the mounting surface‚ ensuring it is level and does not wobble.
Avoid mounting the timer near sources of excessive heat or electromagnetic interference. Proper mounting is crucial for safe and reliable operation‚ preventing accidental dislodgement or damage to the unit.
Wiring Diagram Overview (208-277V DPST)
The Intermatic T104 utilizes a 208-277V DPST (Double Pole‚ Double Throw) configuration‚ demanding careful wiring for safe operation. The timer features screw terminals for connecting the power source (Line 1 & Line 2) and the load (Load 1 & Load 2). Always disconnect power at the breaker before commencing any wiring.
Line 1 and Line 2 connect to the incoming power supply‚ while Load 1 and Load 2 connect to the device you wish to control. Ensure proper grounding for safety; a grounding screw is typically provided. Double-check all connections for tightness and correct polarity.
Incorrect wiring can lead to equipment damage or electrical hazards. Refer to a qualified electrician if you are unsure about any aspect of the wiring process. A clear understanding of the DPST configuration is essential for successful installation.

Programming the Timer
The Intermatic T104 allows for up to 12 ON/OFF operations‚ utilizing trippers to define schedules‚ offering versatile control for diverse applications and needs.
Understanding ON/OFF Trippers
Trippers are the fundamental components for programming the Intermatic T104 timer‚ dictating when connected devices switch ON and OFF. These small‚ plastic pegs are strategically positioned around the timer’s dial‚ representing specific times and durations for operation. Each tripper corresponds to an ON or OFF cycle.
To activate a time slot‚ an ON tripper is placed on the dial‚ while an OFF tripper signals the device to cease operation. The timer features 12 available ON/OFF operations‚ allowing for complex scheduling. Proper placement of these trippers is crucial for accurate and reliable control of lights‚ pumps‚ or HVAC systems. Understanding their function is key to maximizing the timer’s capabilities and tailoring it to specific needs.
Setting the Current Time and Date
Accurate time and date setting is paramount for the Intermatic T104 timer to function correctly. Begin by locating the time-setting dial‚ typically found on the timer’s face. Rotate the dial clockwise until the current time aligns with the 12 o’clock position. Note that the T104 is a 24-hour timer‚ so ensure you’re using the correct format (e.g.‚ 16:21 for 4:21 PM).
The timer doesn’t inherently display the date; its programming revolves around the time of day. However‚ accurate time ensures schedules activate at the intended moments. Double-check the setting against a reliable time source. Incorrect time will lead to misaligned schedules and operational errors. Regular verification‚ especially after power outages or daylight saving adjustments‚ is recommended.
Programming Daily Schedules
The Intermatic T104 timer excels at creating customized daily schedules using its ON/OFF trippers. Each tripper represents a specific ON or OFF time. To program‚ position the trippers around the timer dial‚ aligning them with the desired activation times. Remember the T104 supports up to 12 ON/OFF operations per day‚ offering granular control.
Ensure each tripper is firmly seated in its slot. For a simple schedule‚ use only a few trippers. For complex schedules‚ utilize all 12. Consider the 24-hour clock format when setting times. Test the schedule by manually advancing the time to an activation point to verify correct operation. Repeat this process for each tripper to confirm the entire schedule functions as intended.
Utilizing the 12 ON/OFF Operations
The Intermatic T104 timer’s strength lies in its capacity for 12 distinct ON/OFF operations daily. This allows for highly customized scheduling‚ far beyond simple on/off cycles. Each operation is defined by a paired tripper – one for the ON time and one for the OFF time. Strategically place these trippers around the dial to dictate when connected devices activate and deactivate throughout the day.
Leverage all 12 operations for complex lighting schemes‚ irrigation systems‚ or equipment control. For example‚ stagger lights for a more natural appearance or implement multiple irrigation cycles. Remember to consider the time intervals between operations; shorter intervals create rapid cycling‚ while longer intervals provide extended run times. Careful planning maximizes the T104’s scheduling potential.

Advanced Timer Functions
Explore features like manual override‚ holiday mode‚ daylight saving adjustments‚ and customizable cycle settings (1-12 cycles) for enhanced control and scheduling flexibility.

Manual Override Mode
The Intermatic T104 timer incorporates a convenient manual override function‚ allowing users to temporarily bypass the programmed schedule without permanently altering settings. This feature is invaluable for situations requiring immediate control‚ such as unexpected lighting needs or adjustments to equipment operation.
To engage manual override‚ simply switch the timer to the “ON” or “OFF” position‚ overriding the programmed schedule until the next scheduled operation. The timer will revert to its programmed schedule automatically at the next designated ON or OFF time. This ensures that temporary adjustments do not disrupt long-term scheduling.
Remember to return the timer to the “AUTO” position to resume normal‚ programmed operation. The override function provides a flexible solution for immediate needs while maintaining the integrity of your established schedule‚ enhancing the timer’s overall usability.
Holiday/Vacation Mode
The Intermatic T104 timer doesn’t explicitly feature a dedicated “Holiday/Vacation Mode” but achieves similar functionality through careful programming and the manual override function. Users can simulate occupancy by setting specific ON/OFF times that mimic normal activity during their absence.
Alternatively‚ utilizing the manual override‚ you can set the timer to a constant ON or OFF state for the duration of your trip. This is particularly useful for security lighting or shutting down non-essential equipment to conserve energy.
Before departing‚ ensure you’ve planned your desired operation and either programmed it into the schedule or engaged the manual override. Remember to return the timer to “AUTO” upon your return to resume the regular programmed schedule‚ ensuring seamless control and convenience.
Daylight Saving Time Adjustment
The Intermatic T104 is a mechanical timer and does not automatically adjust for Daylight Saving Time (DST). Therefore‚ manual adjustment is required twice a year to maintain accurate timekeeping and scheduling.
To adjust for DST‚ carefully rotate the timer dial forward one hour in the spring and backward one hour in the fall. It’s crucial to perform this adjustment slowly and precisely to avoid disrupting the programmed ON/OFF schedules.
After adjusting the time‚ verify that all programmed events are still aligned with your desired operating times. Consider noting the adjustment date to simplify the process in future years. Regular checks ensure the timer continues to function reliably and efficiently‚ providing consistent control over connected devices.
Cycle Settings (1-12 Cycles Per Day)
The Intermatic T104 timer offers exceptional flexibility with its cycle settings‚ allowing for up to 12 ON/OFF operations within a single 24-hour period. This feature is particularly useful for applications requiring frequent switching‚ such as irrigation systems or complex lighting schemes.
Each cycle is defined by a pair of trippers – one for the ON time and one for the OFF time. To utilize multiple cycles‚ strategically position additional trippers around the timer dial‚ ensuring they don’t overlap or conflict with existing settings.
Carefully consider the duration of each ON and OFF period to match the specific needs of the controlled device. Proper cycle configuration maximizes energy efficiency and optimizes performance.

Troubleshooting Common Issues
Addressing problems like timers failing to activate‚ trippers not engaging‚ wiring faults‚ or override malfunctions ensures optimal performance and longevity of your Intermatic T104.
Timer Not Turning ON/OFF
If your Intermatic T104 timer isn’t switching as programmed‚ begin by verifying the correct time and date are set; Ensure the trippers corresponding to the desired ON/OFF times are properly positioned around the dial – they are crucial for operation.
Next‚ meticulously check all wiring connections‚ confirming they are secure and match the 208-277V DPST wiring diagram. A loose connection is a frequent culprit. Confirm sufficient load is connected; the timer requires a load to function correctly.
Test the manual override function; if it works‚ the mechanism itself isn’t faulty. If the timer still fails‚ inspect the trippers for damage. Finally‚ consider the possibility of a faulty timer mechanism requiring replacement‚ especially in older units.
Trippers Not Engaging
When Intermatic T104 trippers fail to engage‚ the first step is a visual inspection. Check for any physical damage to the trippers themselves – cracks or bends can prevent proper function. Ensure they are correctly positioned on the timer dial‚ aligned with the desired ON and OFF times.
Verify the trippers are fully seated in their slots; sometimes they can become slightly dislodged. Gently try repositioning them. Confirm the timer’s internal mechanism isn’t obstructed. A buildup of dust or debris can hinder movement.
If the problem persists‚ consider the age of the timer; older mechanisms may experience wear and tear. Replacement trippers or a complete timer mechanism might be necessary for reliable operation;
Wiring Connection Problems
Incorrect or loose wiring is a frequent cause of Intermatic T104 timer malfunctions; Begin by completely disconnecting power at the breaker before inspecting any connections. Verify all wires are securely fastened to the appropriate terminals – the T104 is a 208-277V DPST timer‚ so ensure voltage compatibility.
Check for frayed or damaged wires; replace any that show signs of wear. Confirm the wire gauge is appropriate for the 40 Amp load capacity. A loose neutral connection can also cause issues. Double-check the wiring diagram to ensure correct connections‚ paying close attention to line and load wires.
If using wire connectors‚ ensure they are properly tightened. A multimeter can be used to verify voltage presence and continuity.
Manual Override Malfunction
If the manual override function on your Intermatic T104 timer isn’t working correctly‚ several factors could be at play. First‚ ensure the override switch is fully engaged – sometimes a partial engagement doesn’t fully bypass the programmed schedule. Check for any physical obstructions preventing the switch from moving freely.
A faulty switch mechanism internally could be the culprit‚ potentially requiring timer replacement. Verify the timer hasn’t reverted to its programmed schedule unexpectedly; this might indicate an internal electrical issue. Confirm power is consistently supplied to the timer‚ as intermittent power can disrupt override functionality.
Inspect the trippers; a misaligned or damaged tripper can interfere with the override;

Technical Specifications
The Intermatic T104 operates at 40 Amps‚ 208-277V‚ features a durable indoor metal enclosure‚ and boasts a temperature range for reliable performance.
Voltage and Amperage Ratings (40 Amp‚ 208-277V)
The Intermatic T104 timer is specifically designed for applications requiring robust power handling capabilities. It’s rated for a substantial 40 Amp load capacity‚ making it suitable for controlling a wide range of electrical devices and systems.
This timer operates effectively within a voltage range of 208 to 277 Volts AC‚ accommodating various standard electrical setups commonly found in commercial and industrial environments. The DPST (Double Pole‚ Double Throw) configuration ensures reliable switching of both hot legs of the circuit‚ enhancing safety and performance.
Understanding these voltage and amperage ratings is crucial for ensuring proper operation and preventing damage to both the timer and the connected load. Always verify that your application falls within these specifications before installation.
Dimensions and Enclosure Type (Indoor Metal)
The Intermatic T104 timer features a durable indoor metal enclosure‚ designed to protect the internal mechanism from dust‚ debris‚ and physical impact. This robust construction ensures long-lasting reliability‚ even in demanding environments.
The timer’s dimensions are approximately 2.5 inches in depth‚ 4.7 inches in width‚ and 7.6 inches in height. This compact size allows for flexible mounting options in various locations. The metal enclosure provides excellent shielding against electrical interference and contributes to the overall safety of the device.
It is important to note that the T104 is specifically intended for indoor use only. Exposure to outdoor elements can compromise its functionality and void the warranty.
Operating Temperature Range

The Intermatic T104 timer is engineered to function reliably within a specified temperature range‚ ensuring consistent performance across diverse environmental conditions. Optimal operation is generally achieved within temperatures spanning from 32°F to 122°F (0°C to 50°C).
However‚ prolonged exposure to temperatures outside this range may affect the timer’s accuracy and longevity. Extremely low temperatures could potentially stiffen the mechanical components‚ while excessively high temperatures might lead to premature wear or malfunction.
It’s crucial to avoid installing the timer in locations subject to direct sunlight‚ near heat sources‚ or in areas with poor ventilation‚ as these factors can contribute to temperature fluctuations beyond the recommended limits.
Load Capacity Considerations
The Intermatic T104 timer boasts a robust 40 Amp load capacity at 208-277V‚ making it suitable for a wide array of applications. However‚ careful consideration of the connected load is paramount for safe and reliable operation.
Ensure the total wattage of all devices controlled by the timer does not exceed the maximum rating. Exceeding this limit can lead to overheating‚ timer failure‚ or even a potential fire hazard.
For inductive loads like motors and compressors‚ it’s advisable to apply a safety factor‚ derating the timer’s capacity by 20-30% to account for inrush currents. Always verify compatibility with the specific load type before installation.

Safety and Maintenance
Prioritize electrical safety during installation and maintenance; regularly inspect the timer for damage and ensure proper cleaning to maintain optimal performance.
Electrical Safety Guidelines
Always disconnect power at the breaker before installing or servicing the Intermatic timer to prevent electrical shock. Verify the voltage and amperage ratings align with your application – this model handles 40 Amps at 208-277V.
Ensure all wiring connections are secure and conform to local electrical codes; loose connections can create hazards. Never work with wet hands or in damp environments.
The timer is designed for indoor use within a metal enclosure‚ protecting it from the elements. Avoid overloading the timer‚ as exceeding its capacity can cause overheating and potential fire risks. If you are unfamiliar with electrical work‚ consult a qualified electrician for assistance. Regularly inspect wiring for fraying or damage‚ replacing as needed.
Cleaning and Inspection Procedures
To maintain optimal performance of your Intermatic T104 timer‚ regular cleaning and inspection are crucial. Before any inspection‚ always disconnect power at the breaker. Use a dry or slightly damp cloth to wipe down the exterior metal enclosure‚ avoiding harsh chemicals or abrasive cleaners.
Inspect wiring connections annually for tightness and corrosion. Look for any signs of damage to the wires themselves‚ such as fraying or cracking. Check the trippers for smooth operation and ensure they are securely attached.
Visually examine the timer mechanism for dust buildup; a gentle brush can remove it. Do not attempt to disassemble the timer beyond the enclosure – this could void the warranty and compromise safety. Document any findings and address issues promptly.
Replacing the Timer Mechanism
If the Intermatic T104 timer mechanism fails‚ replacement is often more cost-effective than replacing the entire unit. Always disconnect power at the breaker before beginning. Carefully remove the timer from its enclosure‚ noting the wiring configuration – photographing it is highly recommended.
Purchase a compatible replacement mechanism‚ specifically a T100 Series mechanism like the T104MD89. Disconnect the wires from the old mechanism‚ and carefully connect them to the corresponding terminals on the new one‚ referencing your photograph.
Ensure all connections are secure before re-installing the mechanism into the enclosure. Test the timer thoroughly after restoring power to verify proper operation. If unsure‚ consult a qualified electrician.
Warranty Information
Intermatic timers‚ including the T104 model‚ are generally covered by a limited warranty against defects in materials and workmanship. The standard warranty period is typically one year from the date of purchase‚ though this can vary depending on the distributor and specific product line.
This warranty does not cover damage resulting from improper installation‚ misuse‚ abuse‚ or acts of God. To make a warranty claim‚ retain your proof of purchase and contact Intermatic customer support or the original point of sale.
Warranty service may involve repair or replacement of the defective part‚ at Intermatic’s discretion. Always register your product online for faster claim processing and to receive important updates.